Journal: Clinical and Experimental Dental Research
Article Title: Impact of Various Sleeve Materials on Temperature Variations During Guided Endodontic Access Cavity Preparation Utilizing Finite‐Element Analysis
doi: 10.1002/cre2.70260
Figure Lengend Snippet: 3D models: (a) sleeve and tooth micro‐CT scan results, (b) 3D model of sleeve, (c) finite‐element models with all components, and (d) loading and boundary conditions †1: Drill, 2: Inner Sleeve, 3: Outer Sleeve, 4: Flowable Resin, 5: Template Resin, 6: Enamel, 7: Dentin, 8: Gypsum Base, 9: Drill Support, 10: Thermometer , (e) Experimental Test Illustration, and (f) Experimental Test Configuration.
Article Snippet: Finite element (FE) models were developed from 3D geometries using the Abaqus software.
Techniques: Micro-CT, Gypsum